Add to Cart
Accessories Included: | No |
Automatic Buffer Recognition: | Yes |
Backlight: | Yes |
Calibration: | Demal (1D/ 0.1D/ 0.01D); |
Molar (0.1M/ 0.01M/0.001M); | |
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);; | |
Standard sea water; | |
User defined | |
Calibration Intervals/Alerts/Reminder: | Off, selectable from 2 hours to 7 days |
Certifications: | CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS |
Data Export: | USB connection to PC or USB storage device (limited to the storage device capacity). |
Data Memory: | 5000 data points |
Data Storage: | Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode. |
Dimensions (H x W x D): | 63 mm x 97 mm x 220 mm |
Display: | Up to 3 parameters at a time, dependent on HQ model |
Display Lock Function: | Continuous / Auto-stabilisation ("press to read") / At Interval |
Display Type: | 536x336 Mono-TFT |
Enclosure Rating: | IP67 (with battery compartment installed) |
GLP Features: | Date; Time; Sample ID; Operator ID, Calibration |
Inputs: | 1 |
Instrument: | Portable |
ISE Direct Measurement Range: | No |
ISE Electrode Calibration: | No |
Kit?: | Meter only |
Languages: | English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian |
Measurement method: | Probe specific programmed method settings |
Model: | HQ1110 pH/ORP/1 Channel |
mV Measurement at Stable Reading: | No |
mV Measurement Range: | No |
Operating Error Messages: | Clear text error messages displayed |
Operating Humidity: | 90% (non-condensing) |
Operating Interface: | Soft Touch Keypad |
Operating Temperature: | 0 - 60 °C |
ORP Electrode Calibration: | Predefined ORP standards (including Zobell's solution) |
Parameter: | pH/Oxidation Reduction Potential (ORP) |
pH Buffer Sets: | Colour-coded:4.01, 7.00, 10.01 pH; |
IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 | |
DIN: 1.09, 4.65, 9.23 | |
User-defined custom buffer sets | |
pH Electrode calibration: | 1 - 3 Calibration points Calibration summary data logged and displayed |
pH Measurement Range: | 0 - 14 pH |
pH Resolution: | Selectable:0.001/0.01/0.1 pH |
Power supply: | Rechargeable lithium-ion battery 18650 (internal) |
Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external) | |
Probes included: | None |
Probe Type: | Intellical Standard Laboratory or Rugged Field |
Protection Class: | IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external |
Sensor A: | None |
Sensor B: | None |
Sensor C: | None |
Storage conditions:- | -20 - 60 °C, max. 90% relative humidity (non-condensing) |
Temperature Compensation: | Automatic Temperature compensation for pH |
Temperature Measurement: | °C or °F |
Temperature Resolution: | 0.1 °C |
Type of measurement: | Field Measurements |
Warranty: | 12 months |
Weight: | 519 g (Meter only) |
What's included?: | HQ1110 Portable pH/ORP Meter, 1 channel, includes manuals, Li-Ion batteries, USB charger with Power Cable. |