Add to Cart
Endress Hauser Digital oxygen sensor Oxymax COS61D-AAA1A3
SPECIFICATIONS
Measuring principle:Optical oxygen measurement
Application:Aeration tank, river monitoring, water treatment, fish farming
Characteristic:Digital, optical measurement of dissolved oxygen based on fluorescence quenching Measurement possible in still water
Measurement range:0 to 20 mg/l;0 to 200 %SAT;0 to 400 hPa
Measuring principle:Oxygen-sensitive molecules (marker) are integrated in an optical active layer (fluorescence layer). The fluorescence layer surface is in contact with the medium. The sensor optics are directed at the back of the fluorescence layer. The sensor optics transmit green light pulses to the fluorescence layer. The markers respond (fluoresce) with red light pulses. The duration and intensity of the response signals depend directly on the oxygen contents or partial pressure.
Design:Calibration data saved in sensor:High degree of EMC protection
Material:Sensor shaft: stainless steel 1.4435;Membrane cap: POM
Dimension:Diameter: 40 mm (1.57 inch);Shaft length: 186 mm (7.32 inch)
Process temperature:-5 to 60 °C(20 to 140 °F)
Process pressure:Max. 10 bar abs(Max. 145 psi)
Temperature sensor:NTC 30K
Connection:Process connection: G1, NPT 3/4";Cable connection: fixed cable or TOP68 plug-in-head
Field of application
Oxymax COS61D is a high-performance, digital oxygen sensor that offers fast, accurate and drift-free measurement. It supports your process with low maintenance, high availability and easy handling. The sensor's long-term stable fluorescence layer is exclusively oxygen-selective (interference-free), ensuring consistently reliable measurement. Thanks to Memosens digital technology, the Oxymax COS61D combines maximum process and data integrity, and facilitates simple lab calibration.
Oxymax COS61D measures the dissolved oxygen concentration in:
Wastewater treatment plants:
- O2 control in the aeration basin
- Process water treatment and monitoring
Water works:
- Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
- Water quality monitoring in rivers, lakes or seas
Utilities of all industries:
- O2 control in the biological treatment
- Process water treatment and monitoring
Fish farming:
- O2 control for optimum growth conditions
Minimum maintenance, maximum availability
Fast, drift-free measurement for precise aeration control and process monitoring
Long-term stability for increased process safety
Outstanding performance in all aeration processes (SBR, Anamox, etc.)
Chemical-free: no electrolyte handling
Related Part Number:
CM442-AAM1A2F011A+AK |
CYK10-G101 |
CYK10-G051 |
COY31-Z |
FMU30-AAHEABGHF |
COS61D-AAA1A4 |
CYK10-E051 |
CPS71D-7TB2G |
CLM253-CD0005 |
CM442-AAM1A2F010A |
FTW31-A2A5AA0A+1 L:600MM |
CPS31-1AC2ESA |
CPS31-1EC2ESA |
DK9CM-2 |
FTL41-AAA2AAAAA2CJAAAAJ L=1000MM |
CPS11-2AA2ESK |
FTM51-AGJ2L4A12AA L=2600MM |
PMP71-AAA2H21GAAAA |
CLM253-ID0005 |
COV45-41TN1 |
CPS11-2BA2ESA |
CPS77E-BA6BBU2 |
CLM223-CD0520 |
CPM253-MR8010 |
CYK10-E101 |
RMA42-AAD+F1H3Z2 |
CM442-AAM1A2F010BZ1 |
CPS11E-AA7BAA2 |
TM131-NDBDJHC4BA5CICB1AH3BA1 |
TM131-NDBDJHC4BA8CICB1AH3BA1 |
CPM253-MR8505 |
71512570 |
TMR35-A1BBADAG1AAA |